Trebor Quantum Series Di Water Heater User Manual

Page 11

Advertising
background image

QUANTUM DI HEATER OPERATION / MAINTENANCE MANUAL

PAGE 11

2.5.c

Machine

Shutdown with door closed

Perform the following sequence of events in the order listed for electrical
energy isolation of the tool:

1. Notify personnel in the area that you are going to shut down the

equipment.

2. Shutdown the system in an orderly fashion.

3. Locate the main incoming power disconnect switch-actuating handle.

4. Move the actuating handle to the "OFF" (down) position.

5. Apply the locking energy isolation device (lock) through the hole in the

actuating handle and secure the lock.

6. Verify that the tool has been isolated and de-energized by attempting

to turn the main power disconnect back to th

e “ON” position and/or by

pressing the machine start button. The machine power must not be
reapplied and/or the machine must not start.

2.5.d Machine Start-Up with door closed

Perform the following sequence of events in the order listed for electrical
re-energization of the tool:

1. Ensure that all hand tools are removed from the equipment and that it

is ready for start-up.

2. Notify personnel in the area that you are going to start-up the

equipment.

3. Open the lock and remove the locking energy isolation device (lock)

from the hole in the actuating handle of the Main Disconnect Switch.

4. Move the actuating handle to the "ON" (up) position.

5. Press the machine start button. The machine should start.

2.5.e

Machine

Shutdown with door open

Perform the following sequence of events in the order listed for electrical
energy isolation of the tool:

1. Notify personnel in the area that you are going to shut down the

equipment.

2. Shutdown the system in an orderly fashion.

3. Locate the main incoming power disconnect switch-actuating handle.

4. Rotate

the rotary disconnect shaft to the "OFF" of “0” (down) position.

5. Insert and rotate the key in the rotary disconnect lock (top left of

rotary disconnect device). Remove the key.

6. Verify that the Tool has been isolated and de-energized by attempting

to turn

the rotary disconnect shaft back to the “ON” or “1” position

and/or by pressing the machine start button. The machine power
must not be reapplied and/or the Machine must not start.

Advertising