QUANTUM DI HEATER OPERATION / MAINTENANCE MANUAL

PAGE 35

Remove steel band clamps, but do not remove clamps used on
modules for connecting the electrical box.

Loosen fluid inlet and outlet fittings on module.

Disengage the inlet fitting by sliding the bottom of heater off shelf.

Lower the heater to disengage top fitting from manifold.

Use an absorbent cloth to remove any liquid from the leak sensor

probe and leak containment well.

Install replacement heater module into cabinet in reverse order from

above. Note: Carefully align the fittings because they can easily be
cross-threaded.

Return failed heater module.

Figure 7-1:

NOTE: Do not disassemble the heater module. There are no user
serviceable parts inside the module. If disassembled, any product
warranties will be invalid.