Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System User Manual
Page 135
Advertising
ULTRA-CUT 400 XT
Manual 0-5275
APPENDIX
A-27
System Bias PCB Test Points
TP1 GND
TP2 2�VDC
TP3 DC INPUT POSITIVE
TP� Vcc1
TP5 Vcc2
TP� GATE
TP7 PRIMARY GND
TP� +12V PRIMARY
TP9 P_ISOL_GND
TP10
DC SENSE POSITIVE
LED Reference
D3
Red
MISSING PHASE
D�
Red
AC V HIGH
D1� Red
AC V LOW
D15 Green VAC_IDA
D2� Green +12V PRIMARY
D27 Green VAC_IDB
D30 Green 2�VDC
D�� Green TRANSFORMER ON