Ultra-cut 400 xt, O position, Water mist is not used in all applications – Tweco 400 XT Ultra-Cut Plasma Cutting System User Manual

Page 73: Gcm 2010

Advertising
background image

ULTRA-CUT 400 XT

Manual 0-5275

OPERATION

4-9

4. Current Control

Adjusts the output current of the power supply.

High Precision

Plasma Cutting System

PREFLOW

H

2

O

MIST

PLASMA

SHIELD

PRESSURE

PLASMA

POWER SUPPLY

GAS

FLOW

High Precision

Plasma Cutting System

ENABLE

DISABLE

GAS

MODE

RUN

SET PREFLOW

SET PLASMA

& SHIELD

TEST

O2 - AIR

O2 - O2

H35 -N

2

F5 - N

2

AIR - AIR

N

2 -

H

2

O

N

2 -

N

2

9

9

Art # A-04767_AC

GCM

2010

AMPERAGE

SET-UP

AMPERAGE

SET-UP

5. Plasma Power Supply Enable / Disable Switch

The DISABLE position removes input power from the Power Supply inverters, disables the coolant pump and fan, the pilot

contactor & HF and removes AC power from the gas control solenoids shutting off all gas flow. When the switch is returned

to the ENABLE position an automatic gas purge is started and then the system is returned to normal operation under control

of the CNC device.

6. PREFLOW Control Knob and Pressure Gauge

Used to set preflow gas pressure and flow. MODE switch must be in SET PREFLOW position.

7. PLASMA and SHIELD Control Knobs, Pressure Gauges and Flow Meter

Used to set plasma and shield gas pressures and flows. Mode switch must be in SET PLASMA & SHIELD position.

8. Gas Pressure Flow Switch

At lower flow rates shield gas pressure is first set per the cut charts then the flow is set using the flow meter with the GAS

switch set in the FLOW position. Some torch parts require higher flow rates that exceed the capacity of the flow meter. In

that case, Gas switch is set in the PRESSURE position and the regulator and gauge is used to set pressure per the cut charts

when no “Ball” setting is shown.

9. H

2

O Mist Control Knob and Flow Meter

Used to set water flow rate. MODE switch must be in SET PLASMA & SHIELD position. GAS selection switch must be in

N

2

-H

2

O position.

NOTE

Water mist is not used in all applications.

Advertising