Ultra-cut 400 xt – Tweco 400 XT Ultra-Cut Plasma Cutting System User Manual

Page 158

Advertising
background image

ULTRA-CUT 400 XT

A-50

APPENDIX

Manual 0-5275

Reasons why RAS Control relay would not close:

�. Pilot current flowing. There actually is pilot current flowing somewhere. Unlikely as it would normally set the 20� fault

but we have to rule it out.

a. Disconnect J�1 on the Pilot board, if HF still doesn’t fire and the Relay board Pilot LED, D11, is still on, it’s due

to a fault in the detection circuits.

7. Faulty detection circuit. There isn’t any pilot current but a fault in the circuits measuring pilot current is indicating there

is current.

a. Measure between pins � (-) and 9 (+) on the Pilot ribbon cable from Relay board J3 to Pilot board J�2. If there is

no pilot current it should be zero. Anything else indicates the Pilot board current sensor is faulty causing the Relay

board D11 to be on. Replace the Pilot board assembly.

b. If the Pilot current signal on the pilot ribbon cable was zero, measure between pins 23 (-) and 25 (+) on the �0 pin

ribbon cable between the Relay board and the CCM. This would also normally be zero if there is no pilot current.

Anything else would indicate the Relay board is faulty.

Art # 12307

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

J23

TO RELAY BOARD

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

J4

From I/O PCB

24VDC_SW

D21

GREEN

D23

RF ON

1

5

3

4

K2

RAS CONTROL

120

VA

C

120 VAC to RAS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

J8

120

VA

C

R

ET

120 VAC_1

From J9-1

120 VAC_RET

From J9-7

CCM I/O Board

Relay & Interface Board

1

2

3

4

5

6

7

8

9

10

11

12

13

14

J59 - RAS

(98)

(99)

T2

120 / 6000 VAC

(98)

(99)

6.5K 1W

6.5K 1W

AC200XT only

(Rear Panel)

TP1

GND

TP1

GND

/ RAS ON

�. If “ /RAS ON” signal is low on pin 1� of the �0 pin ribbon cable, relative to TP1 on the CCM I/O board, during the ignition

time then we need to determine if the Relay board is defective. If /RAS ON signal is not low the CCM or the �0 pin ribbon

cable may be defective.

a. If the Relay board RF ON LED, D23, is not on while the /RAS ON signal is low, then the Relay board is defective.

b. Is D23 is on, measure for 120 VAC on J�-3 to J�-11. If not present the Relay board is defective.

c. If 120 VAC is present at J� during the ignition time go back and perform steps 2-�.

Troubleshooting Pilot Board problems.