6 operating the device, 1 selecting a channel, switching on or off, 2 setting the temperature – Weller WR2 User Manual

Page 28

Advertising
background image

8-20

WR 2

6 Operating the device

6.1 Selecting a channel, switching on or off

1. Press one of the ┌ 1 ┐buttons or ┌ 2 ┐ (7) to select one of two

channels.

The nominal temperature of the selected channel and the hard

programmed temperatures are displayed in small font.

- Or -

Briefly press the ┌ 1·2 ┐button (11) until the required channel is

displayed.

The current tool temperature then appears on the display. The

status with the corresponding setpoint temperature is also

displayed in the lower area.

The selected channel is indicated by a triangle (21) in the display

and by a red-lit LED (1) on the device.

2. Press the UP (5) and DOWN (6) buttons simultaneously until

three dashes "- - - show up on the display.

3. Release the buttons.

If the channel is now deactivated, "OFF appears on the display.

If the channel is activated, the current actual temperature

appears on the display.

Stored data are not lost when a channel is switched off.

Note The display changes automatically to the channel to which a new

tool has been connected, or if the finger switch has been pressed or

if the tool has been taken out of the switching holder.

This function can be deactivated in Special functions - Menu 2 (see

"Deactivating / activating automatic channel changing", page 17).

6.2 Setting the temperature

Setting the temperature individually
1. Select the required channel by pressing either of the ┌ 1 ┐ or

┌ 2 ┐ buttons.
The display shows the actual temperature values of the selected

channel.

2. Press the UP or DOWN button.

The display changes over to the set setpoint value.

The temperature symbol (18) flashes.

3. Press the UP or DOWN button to set the desired setpoint

temperature:
- Brief touching alters the setpoint value by one degree.
- Permanent pressing alters the setpoint value in rapid pass

mode.

The actual value of the selected channel appears on the display

again approx. 2 seconds after the setting buttons are released.

Advertising