Weller WR2 User Manual

Page 38

Advertising
background image

18-20

WR 2

Activating / deactivating button lock HAP
This function can be used to change the factory-default button

response of the HAP iron. When the lock is enabled, the HAP is

activated on the first press of the button and deactivated on the next

press of the button.
1. Select the menu item HAP LOCK in Menu 2.
2. Set the status with the UP or DOWN button.

(ON = activate / OFF = deactivate)

3. Change to the next menu option using the ┌ 1 ┐ (back) or ┌1·2 ┐

(forwards) button.

Note To protect itself, the pump switches off automatically after

20 minutes of continuous operation.

Setting the control characteristic for WP 120
The HI / LO CONTROL function can be used to set the control

characteristic for WP 120 (set to HI at the factory):
1 Select menu option HI / LO in Menu 2.
2. Set the status with the UP (HI) or DOWN (LO) button.
HI: aggressive control response for maximum output - temperature

overshoots are possible

LO: sensitive control response for heat-sensitive components

8 Resetting to factory settings

Resetting the special functions
This function is described under "7.1 Selecting special functions of

Menu 1"Resetting the special functions to the factory settings" on

page 11.

Resetting calibration to factory settings
This function is described under "7.2 Selecting special functions of

Menu 2"Calibrating to factory settings" on page 17.

9 Care and maintenance of WR 2

9.1 Servicing the filter

Regularly check the main filter for VACUUM” and AIR” and replace if

necessary.

WARNING!

Working without a filter can result in irreparable

damage to the vacuum pump.

Z

Check before starting soldering whether a main filter is

inserted.

Advertising