Weller WR2 User Manual

Page 31

Advertising
background image

WR 2

11-20

DE

EN

FR

IT

ES

PT

NL

SV

DK

FI

GR

TR

CZ

PL

HU

SK

SL

EE

LV

LT

Resetting the special functions to the factory settings
1. Press and hold down button ┌ 2 ┐.
2. Then press the UP and DOWN buttons simultaneously.

"FSE" appears on the display.

The repair station is now reset to the factory settings.

Setting the standby temperature
The standby temperature is automatically set after a temperature

deactivation. The actual temperature flashes in the display.

"STANDBY appears on the display.
1. Select the menu item STANDBY in Menu 1.
2. Set the setpoint value for the standby temperature with the UP or

DOWN button.

3. Change to the next menu option using the ┌ 1 ┐ (back) or ┌1·2┐

(forwards) button.

4. Change channel using the AIR (12) button.

Setting temperature deactivation (SETBACK)
When the soldering tool is not in use, the temperature is reduced to

the standby temperature after the set setback time has elapsed. The

setback state is indicated by a flashing actual value and "STANDBY

appears on the display. Pressing the UP or DOWN button terminates

this setback state. Depending on the tool, the finger switch or the

switching holder deactivates the setback state.
The following setback settings are possible:

"0 min: setback OFF (factory setting)

"ON: setback ON (the system is controlled down to standby

temperature with the switching holder after the soldering bit is

stowed)

"1-99 min: setback ON (individually settable setback time)

1. Select the menu item SETBACK in Menu 1.
2. Set the setback value with the UP or DOWN button.
3. Change to the next menu option using the ┌ 1 ┐ (back) or ┌1·2┐

(forwards) button.

Setting the automatic switch-off time (AUTO-OFF)
When the soldering tool is not in use, heating of the soldering tool is

switched off after the AUTO-OFF time has elapsed.
Temperature deactivation is performed independently of the set

setback function. The actual temperature flashes in the display and

serves as residual-heat indicator. "OFF appears on the display. A

flashing dash appears on the display below 50 °C (120 °F).

The following AUTO-OFF time settings are possible:
The following AUTO-OFF time settings are possible:

"0 min: AUTO-OFF function is switched off

"1-999 min: AUTO-OFF time, individually settable

1. Select the menu item OFF in Menu 1.
2. Set the AUTO-OFF setpoint time value with the UP or DOWN

button.

3. Change to the next menu option using the ┌ 1 ┐ (back) or ┌1·2┐

(forwards) button.