ClearOne Converge Pro User Manual

Page 282

Advertising
background image

277

FEDR – Feedback Elimination Dynamic Node Reset

This command will reset only the dynamic filters on the feedback eliminator. There is no query associated with this
command.

Command Form

: DEVICE FEDR <CHANNEL> <GROUP>

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Reserved

Zero

2

Value:0-16
(Null to query in text)

Nodes

FEF – Feedback Elimination Fixed Filter

This command sets the number of fixed filter to use in the feedback eliminator. The fixed filters number will be
used during the initialization phase when gain is increased until feedback occurs. A fixed filter will be set at the
feedback point during the initialization.

Command Form

: DEVICE FEF <CHANNEL> <GROUP> [VALUE]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Reserved

Unsigned Short

2

Zero

-

FEG – Feedback Elimination Auto Gain Max

This command sets the target gain for auto setup in feedback cancellation.

Command Form

: DEVICE FEG <Channel> <Group> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Reserved

Unsigned Short

2

0 - 8
(Null to query in text)

dB

FEGL – Feedback Elimination Gain Level

This command reports the gain value achieved at the end of the feedback automatic setup. The maximum value
possible is set in the FEG command. This is a query only command.

Command Form

: DEVICE FEGL <Channel> <Group> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Value

Signed Float

2

-99.99 to 99.99
(Sent with Null, value returned)

dB

FELD – Feedback Elimination Lock Depth

This command sets the operation of a fixed filter node to be either locked or unlocked. In locked mode, the fixed
filter’s depth will remain the same after all the fixed filters are placed. In unlocked mode, the fixed filter’s depth can
be modified anytime until the maximum depth is achieved.

Command Form

: DEVICE FELD <Channel> <Group> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Value

Unsigned Float

2

0 = Locked
1 = Unlocked
Default 0
(Null to query in text)

-

Advertising