FILTSEL – Filter Select

This command turns on and off the filters.

Command Form

: DEVICE FILTSEL <Channel> <Group> <Node> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

3, 5, 23, 29 (M, P, J, V)

-

Node

Unsigned Integer

1

Group 3, 23, 29

1 – 4
0xFF for all (*
text)

-

Group 5

1 – 15
0xFF for all (*
text)

Value

Unsigned Integer

1

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

FLOW – Flow Control

This command selects/reports the flow control of the serial port on the unit. Hardware flow control is implemented
using DTR and DSR.

Command Form

: DEVICE FLOW [Value]

Argument Type

Size

Values

Units

Value

Unsigned Integer

4

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

FMP – First Mic Priority Mode

This command selects/reports first Mic priority mode.

Command Form

: DEVICE FMP <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

4 (G)

-

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

GAIN – Gain Adjustment

This command changes or reports back the gain for a channel.

Command Form

: DEVICE GAIN <Channel> <Group> [Value] [Absol/Rel]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17, 25, 26 (I, J, O, M, P, L, F, T, R, K, Z,
D, U, V)

-

Value

Signed
Float

2

-99.90 – 99.90 **
(Null to query in text)

dB

Absol / Rel

0

A = Absolute
R = Relative
Null = Relative

-

NOTE: Values indicate valid range for entry values only. Actual internal range of the gain stage