ClearOne Converge Pro User Manual

Page 307

Advertising
background image

302

RESET – Reset

Resets the unit. There is no query for this command.

Command Form

: DEVICE RESET

No Arguments

RING – Ring Indication

This command indicates a ringing line. This command is reportable only. It cannot be queried or set.

Command Form

: DEVICE RING <Channel><Value>

Argument

Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

17 (R)

-

Value

Unsigned
Integer

2

0 = Ring Cycle Ended
1 = Ring Cycle Started

-

RINGEREN – Audible Ring Enable

This command sends/reports the use of an audible ring.

Command Form

: DEVICE RINGEREN <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

17 (R)

-

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

RINGERLVL – Audible Ring Level

This command selects/reports the audible ring’s level.

Command Form

: DEVICE RINGERLVL <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

17 (R)

-

Value

Signed Float

2

-12.00 – 12.00 (dB)
(Null to query in text)

-

RINGERSEL – Audible Ring Melody Selection

This command sends/reports the audible ring melody.

Command Form

: DEVICE RINGERSEL <Channel> [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

17 (R)

-

Value

Unsigned Integer

2

1 – 3
(Null to query in text)

-

RINGERTEST – Audible Ring Melody Test

This command plays the current audible ringer melody. This command is executable only. There is no query.

Command Form

: DEVICE RINGERTEST <Channel>

Argument

Type

Size

Values

Units

Channel

Channel

1

See

Groups and Channels

-

Group

Group

1

17 (R)

-

Reserved

Unsigned Integer

2

0

-

Advertising