Please read these notes before commencing installation.

AH10 AA-B

BUS audio hhub

A-BUS is a standard that allows some compatibility between

different manufacturers A-BUS multi-room products. The AH10 can

be switched between Incognito A-BUS or standard A-BUS mode. The

Incognito A-BUS position is for use with our own Incognito KP10

keypad and gives extra functions. When used with other manufac-

turers A-BUS keypads it should be set to standard A-BUS or they will

not work. The switch is located on the rear of the AH10 (see below).

Fix to a hard surface such as a cupboard surface, not to carpet or a

soft-lined surface, as this will inhibit airflow through the unit. Do not

situate in close proximity to any installation which will produce

excessive electrical noise such as dimmer racks etc (these may

interfere with the unit). Situate within three metres of a power socket.

VH10 vvideo hhub

Locate in close proximity to the AH10 (maximum of five metres away).

Fix to a hard surface such as a cupboard surface, not to carpet or a

soft-lined surface, as this will inhibit airflow through the unit.

Do not situate in close proximity to any installation which will

produce excessive electrical noise such as dimmer racks etc; these

may interfere with the unit.

Wiring tto zzones

Run a Cat-5e cable from the AH10 to each wall control unit.

Fit a single-gang back box for each KP10.

Run two standard speaker cables from the KP10 to mounted

loudspeakers. If video is required, run CT100/RG6 high-quality co-

axial cable from the VH10 main zone connection either directly to

the video display, or to a wall-mounted panel fitted with a suitable

phono/RCA connector.

Cabling ttips

Cat5e cable should be run through the installation in electrical conduit,

either metal, non-metallic, rigid or intermediate, wherever possible.

Should conduit not be available or impractical, cabling running through

frames or beams must be a minimum of 25mm/1inch from the

nearest edge of that structure. If the frame or beam is metallic, then

the cable should be protected by a bush or grommet.

When routing cables around the installation, care must be taken to

prevent kinking and trapping. Any cable ties used must not be

tightened any more than is necessary to hold the cable in place.

Always re-check the colour code of the Cat5e cable connections to

ensure they are correct.