Defining an ebl/vrm marker, Placing ebl/vrm markers by using the cursor, Offsetting an ebl/vrm marker – B&G Zeus2 Glass Helm CPU User Manual

Page 64: Setting a guard zone around your vessel, Defining a guard zone, Alarm settings, Sensitivity

Advertising
background image

Defining an EBL/VRM marker

1.

Ensure that the cursor is not active

2.

Activate the menu, select EBL/VRM, then select EBL/VRM 1 or EBL/VRM 2

- The EBL/VRM is now positioned on the radar image

3.

Select the adjustment option from the menu if you need to reposition the marker, then
adjust the marker by dragging it into position on the radar image

4.

Select the save option in the menu to save your settings

Placing EBL/VRM markers by using the cursor

1.

Position the cursor on the radar image

2.

Activate the menu

3.

Select one of the EBL/VRM markers

- The EBL line and the VRM circle will be positioned according to the cursor position

Offsetting an EBL/VRM marker

1.

Ensure that the cursor is not active

2.

Activate the menu, select EBL/VRM, then select the marker you wish to offset

3.

Select the set offset option

4.

Position the cursor on the radar panel to set the offset position

5.

Select the save option in the menu to save your settings.

You can reset the EBL/VRM center to vessel position from the menu.

Setting a guard zone around your vessel

A guard zone is an area (either circular or a sector) that you can define on the radar image.
When activated, an alarm will alert you when a radar target enters or exits the zone.

Defining a guard zone

1.

Ensure that the cursor is not active

2.

Activate the menu, select Guard zones, then select one of the guard zones

3.

Select the shape for the zone

4.

Select Adjust to set the range and depth for the guard zone. The values can be set from the
menu or by dragging on the radar panel

5.

Select the save option in the menu to save your settings.

When positioned, you can turn the guard zones on/off by selecting the relevant section on
the data bar.

Alarm settings

An alarm will be activated when a radar target breaches the guard zone limits. You can select
if the alarm will be activated when the target enters or exits the zone.

Sensitivity

The guard zone sensitivity can be adjusted to eliminate alarms for small targets.