11

Controls

The RS series of units is equipped with a normally closed inlet valve. This

means that when the unit is started, the inlet valve remains closed while

the unit builds up pressure by means of a bypass line. After startup

the inlet valve is controlled by a simple on/off action of a pressure switch

working with a solenoid valve.
For instrumentation the unit has a discharge temperature gauge, air

pressure gauge

Installation

General

The standard RS series was designed for indoor applications. For

outdoor applications consult the factory for modifications. Failure to

obtain factory approval will void the warranty.
Foundation

Your Compressed Air Systems LLC rotary screw compressor does not

require a special foundation. However, it is necessary that the floor be

level and the frame adequately supported. Consult the SPECIFICATIONS

section of this manual for the compressor weight and dimensions. We do

recommend that the compressor be bolted to the floor. We recommend

the compressor be mounted on vibration reduction pads
Room

The room should be of adequate size to provide full access to the

machine for routine maintenance. It should have ventilation to keep the

room as cool as possible. Operating at elevated temperatures will cause

nuisance overload and temperature shutdowns. Room temperature

should not exceed 1100 F.
Air Intake

To achieve the longest filter and lubricant life and the least maintenance

you need to supply the compressor with the cleanest air possible. It must

not contain any flammable or toxic gases. These will be concentrated

by the compressor, and could result in personal injury or death and

property damage.

WARNING

Inlet containing reactive gases will cause the failure of the lubricant and

compressor. Insure an air supply that is well clear of any reactive gas source.

If it is necessary to take air from a remote source, the piping should be

at least the diameter of the air filter inlet. For distance over twenty feet

the diameter needs to be enlarged to reduce the restriction. This pipe

should also be corrosion resistant and free from scale and dirt. The inlet

should also be covered to prevent rain and small animals from entering.