15

Storage

In some cases it may be necessary to store the compressor for extended

periods of several months before placing the unit in operation. When this

is required do the following:
Cover and seal all machine openings to prevent the

entrance of water and dirt.
Cover all openings in open drip proof motors to prevent

the entrance of rodents.
If the storage conditions are below freezing; drain the after cooler,

traps, water-cooled heat exchanges and attendant piping. We do not

recommend outside storage.
Cover with a waterproof tarpaulin that can easily be removed for in-

storage maintenance.
While in storage, every two or three months, rotate the compressor

and motor by hand to prevent flat spots on the bearings that will lead to

premature failure.
At the end of the storage period, follow the uncrating and start-up

procedures. If the unit has been stored for more than eighteen months,

you should contact Compressed Air Systems before restarting the

compressor.

Guidelines

The air pressure drop between the compressor and the point of use is

not recoverable.
Pipe size should be large enough that the pressure drop does not exceed

10% between the air receiver and the point of use.
Arrange the air distribution piping to avoid the following types of strain:

Strains that are due to dead weight of the pipe itself.
Strains that are due to expansion or contraction of the piping due to

temperature.
Strains due to internal pressure within the pipe.
Design inlet and discharge piping for smooth airflow.
Plan for future emergencies and establish an area of the loop to install a

temporary compressor.
Consider a second receiver at the end of the line or opposite side of the

loop.

installation

/

guidelines