Problem

Possible Cause

Solutions

Compressor

does not build

up to

pressure

1. Air leaks in shop

2. Inlet valve malfunction

3. Compressor belts slipping

4. Air demand exceeds

compressor output

5. Pressure switch set to low

6. Solenoid valve malfunction

7. Compressor rotors damaged

1. Find and fix shop air leaks

2. Check inlet valve for proper

function

3. Check air usage requirements

on machinery and check for

shop air leaks

4. Check pressure switch for

proper setting

5. Check solenoid for proper

function

Compressor will

not load to

compress air

1. Pressure switch set to high

2. Inlet valve malfunction

3. Faulty solenoid

1. Check pressure switch for

proper setting

2. Check inlet valve for proper

function

3. Check solenoid for proper

function

CFM Flow (air

flow) seems low

1. Restricted air intake filter

2. Inlet valve partially closed

3. Air pressure set to high

4. Insufficient oil flow

5. Solenoid valve malfunction

Excessive oil

consumption

1. Over filled sump

2. Broken oil line

3. Plugged oil return line

4. Damaged or dirty separator

5. Excessive unloaded compressor

run time

1. Check sump for proper oil level

2. Check all lines for cracks

3. Replace separator

4. Add a timer to the system

High tempera-

ture shutdown

1. High ambient air temperature

around compressor

2. Low oil level in compressor

3. Plugged oil filter

4. Restricted air flow over cooler

5. Thermal by pass leaking

6. Faulty temperature switch

1. Lower ambient temperature

around compressor

2. Check unit for proper oil level

3. Replace oil filter

4. Clean oil cooler

5. Check thermal bypass for

proper operation

6. Check temperature switch for

proper operation.