Cooling Air Discharge

The cooling air discharge must be restriction free. Any louvers or

ducting must not exceed a quarter of an inch static head. Above this

a booster fan will be required. Consult a local HVAC contractor for

recommendations prior to installation. Excessive restriction to the cooling

air discharge will cause the unit to operate at elevated temperatures that

could result in high temperature shutdowns. Ducting of cooling air to the

unit is not generally recommended.

Electrical

A qualified electrician in compliance with standards and local codes

should do all electrical wiring. Be sure to investigate the local

requirements before installing the compressor. The power supply should

be adequate and free of parasitic loads that will cause an under voltage

condition during the operation of the compressor, otherwise there will

be nuisance electrical shutdowns. Always connect the compressor to its

power source through a fusible disconnect and insure the unit is

properly grounded.

Unpacking and Handling

Occasionally damage will occur during shipping. Be sure to carefully

inspect the unit before unpacking. After unpacking before you sign the

receiver, if anything damage has occurred, document it with the

trucking firm immediately. Contact your Compressed Air Systems LLC.

representative for assistance.
To move your compressor to its installation site we recommend that you

leave the unit on its shipping skid as long as possible. The forks should

be extended the width of the compressor and padding should be placed

between the compressor and the truck boom.
If it is necessary to lift the compressor with a crane, we recommend the

use of the spreader bar and chains. The spreader bar should be greater

than the width of the compressor and padding is placed on

the edges to prevent chain damage. Consult the installation drawing at

the end of this section for the center of gravity.