Compressor, Installation – BE Pressure supply 80 Gallon Enclosed Rotary Screw Compressor AC1080SQ User Manual

Page 13

Advertising
background image

13

Location

Locate the compressor in an indoor area that is clean, dry, well lighted,

and well ventilated, with sufficient space for safe and proper inspection

and maintenance. Ambient temperatures should not exceed 104 degrees.

For fall below 30 degrees unless an electric motor rated for a higher

temperature is used. Inspection and maintenance checks are required

daily, therefore, ample space is required around the compressor.

The compressor must not be installed closer than fifteen inches from a

wall or from another compressor to allow ample circulation or air across

the compressor cylinders and head, and through the coolers if they are

part of the system. Additional safety can be achieved by locating the

pulley guard next to the wall.

Mounting

We recommend the use of rubber pads or isolators between the tank

legs and the floor. If a shim is required to level the unit, place it between

the pad and floor. If you bolt the unit to the floor, use the bolts as

guide pins and do not tighten the bolts. The rubber pads are used to

absorb machine vibration and cannot

work effectively if bolted tightly.

Induction System

Do not locate the compressor where it could ingest or ignite toxic,

explosive or corrosive vapors, ambient air temperatures exceeding 104

degrees F, water or extremely dirty air. Ingestion of any of the above noted

atmospheres by the compressor could jeopardize the performance of the

equipment and all personnel exposed to the total compressed air system.

Depending on the size of the compressor and the size and construction

of the compressor room it may be necessary to locate the air pickup point

outside the room. Destructive pulsations can be induced by reciprocating

compressors that will damage walls and break windows. Pulsation can

be minimized by adding a pulsation dampener on the inlet side of the

compressor.

CAUTION

Under no circumstances should a compressor be placed in an area that may be

exposed to a toxic, volatile or corrosive atmosphere nor should toxic, volatile or

corrosive agents be stored near the compressor.