Manual Relief And Shutoff Valves

Install a manual relief valve to vent the compressor to atmosphere. In

those instances where the air receiver tank services a single compressor,

the manual relief valve can be installed on the receiver. When a manual

shut- off valve, and a safety relief valve installed upstream from the

manual relief valve. These valves are to be designed and installed as to

permit maintenance to be performed in a safe manner. Never substitute

a check valve for a manual shut-off valve (block valve) if the purpose is to

isolate the compressor from a system for servicing.

Guards

All mechanical action or motion is hazardous in varying degrees and

needs to be guarded. Guarding shall be in compliance with OSHA Safety

and Health Standards 29 CFR 1910.219 in OSHA manual 2206 and any

state or local code.

Drives

It is important that the compressor and motor pulleys are aligned properly

and the V belt is correctly tensioned. Improper pulley alignment and

belt tension are causes for motor overloading, excessive vibration, and

premature belt and/or bearing failure.

CAUTION

Guards must be fastened in place before starting the compressor and never

removed before cutting off and locking out the main power supply.

CAUTION

Excessive speed of the compressor or driver can be lethal. Never operate

the compressor beyond the manufacturer’s recommendation. Bursting of the

flywheel may be the greatest threat because the normal guard may not contain

all the pieces. Crankshaft and connecting rod breakage is a possibility and

compressor efficiency, valve life and bearing life will be abnormally reduced.