Setting an IP Address (SX80)

122

4

Click [TCP/IP], enter appropriate values in the following field, and click the [OK] button.
[IP address]:

IP address of projector

[Subnet mask]:

Subnet mask of projector

[Default gateway]:

Default gateway of network

5

Click [Mail], enter appropriate values in the following field for the error report, and click
the [OK] button.
[To:]:

E-mail address to which error notification message is sent.
(Within 63 alphanumeric characters)

[Cc:]:

Second E-mail address to which error notification mes-
sage is sent (Within 63 alphanumeric characters, can be
omitted).

[From:]:

Sender of E-mail (projector)

[SMTP server IP address]: IP address of available SMTP server
[SNTP server IP address]: IP address of available SNTP server (can be omitted)
[Time zone]:

Time zone of installation site

[Mail resend interval]:

E-mail resend interval if the transmission has failed
Setting range: 0 – 59 seconds (factory default: 10 sec-
onds)

[Mail resend times]:

Number of resend times if the E-mail transmission has
failed
Setting range: 0 – 255 times (factory default: 3 times)

[Error report]:

ON/OFF of error message sending function. Select [ON].
[OFF] is the factory default.