Encoder operating parameters, Encoder operating parameters 4 – Baumer BMxx, GBxxx-GXxxx - EtherCAT / PoE from version&nbsp,5.0 User Manual

Page 7

Advertising
background image

Baumer_EtherCAT_PoE_5-00_MA_EN.docx

7/30

www.baumer.com

30.09.14

Encoder operating parameters

4.

Significance of operating parameters

Product

Device

Name

Resolution per turn

0x6001

Number of turns

0x6502

Measuring range

0x6002

Dezimal

Hex Bit Dezimal

Hex

Bit

Dezimal

Hex

Bit

BMSx

GCAMW_H

4096

1000 12

1

1

0

4096

1000

12

BMMx

GCMMW_H

4096

1000 12 65536

10000

16

268435456

10000000

28

GXAMW(S) GXAMW_H

8192

2000 13

1

1

0

8192

2000

13

GXMMW(S) GXMMW_H

8192

2000 13 65536

10000

16

536870912

20000000

29

GBAMW(S) GBAMW_H

262144

40000 18

1

1

0

262144

40000

18

GBMMW(S) GBMMW_H

262144

40000 18 16384

4000

14 4294967296 100000000

32



The enabled scaling functionality in CoE is prerequisite for further user-specific parameterization
such as resolution, total measuring range, direction of rotation and preset.

See chapter: SDO (Service Data Objects)