EMM-E6 Installation Guide

4-1

CHAPTER 4

TROUBLESHOOTING

This chapter provides diagnostic and troubleshooting information.

4.1

USING LANVIEW LED

S

The EMM-E6 uses the Cabletron Systems built-in visual diagnostic and
status monitoring system called LANVIEW. With LANVIEW, you can
quickly scan the EMM-E6 LEDs to observe network status or diagnose
network problems.

NOTE

The STBY, RCV, XMT, and CLN LEDs are in a matrix, which
provides these indicators for four of the EMM-E6 Ethernet
channels. To read the LEDs, the vertical column indicates the
interface or channel the LED designates, while the horizontal
row denotes the condition or statistic being monitored.

Table 4-1

LANVIEW LED Messages

LED

Color

Description

Error Condition/
Recommended Action

CPU

Green
(Flashing)

Normal operation.

If the LED is not lit, the
EMM-E6 may not be
receiving power. See the
Troubleshooting Checklist.

Red

CPU error condition.

Press the Reset switch on
the EMM-E6 front panel to
re-initialize the board. This
may clear the error. If the
board does not re-initialize, it
has probably failed. Call
Cabletron Systems Technical
Support.