Appendix A: Specifications

A-2

EMM-E6 Installation Guide

A.3

ENVIRONMENTAL REQUIREMENTS

Operating Temperature:

5

°

C to 40

°

C (41

°

F to 104

°

F)

Storage Temperature:

-30

°

C to 90

°

C (-22

°

F to 194

°

F)

Operating Humidity:

5% to 95% (non-condensing)

A.4

CERTIFICATION

Safety:

UL 1950, CSA C22.2 No. 950, EN 60950, and
IEC 950

Emission:

FCC Part 15 Class A, VCCI Class I, and
EN 55022 Class A

Immunity:

EN 50082-1

This unit has been tested by Bellcore and found to comply with the
following Bellcore standards:

TR-NWT-000063

Network Equipment Building System (NEBS)
Generic Equipment Requirements

GR-1098-CORE

EMC and Electrical Safety Generic Criteria for
Network Telecommunications Equipment

A.5

COM PORT PINOUT

Type: Standard RJ45 port

Pin

Function

Connection Attitude

1

Transmit Data (XMT)

From COM 2 port

2

Data Carrier Detect (DCD)

From COM 2 port

3

Data Set Ready (DSR)

To COM 2 port

4

Receive Data (RCV)

To COM 2 port

5

Signal Ground (GND)

NA

6

Data Terminal Ready (DTR)

From COM 2 port

7

Request to Send (RTS)

To COM 2 port

8

Clear to Send (CTS)

NA

ICH1Book Page 2 Tuesday, August 6, 1996 3:06 PM