1028

Fabric OS Command Reference

53-1002746-01

switchStatusPolicyShow

2

switchStatusPolicyShow

Displays the policy parameters that determine the overall switch status.

SYNOPSIS

switchstatuspolicyshow

DESCRIPTION

Use this command to view the current policy parameters set for the switch. These policy parameters
determine the number of failed or nonoperational units allowed for each contributor before triggering a
status change in the switch. For port-related contributors, the numbers are expressed as a percentage of
physical ports present in the switch at any given time.

The command displays the current parameters in a three-column format. Refer to the Examples section
for an illustration. The first column indicates the contributor, the second column indicates the minimum
number that contributes to the DOWN status, and the third column indicates the minimum number that
contributes to the MARGINAL status. The policy parameters are set by the switchStatusPolicySet
command. Not all policies are supported on all platforms. Refer to the switchStatusPolicySet help page
for more information.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

None

EXAMPLES

To display the switch policy parameters Brocade DCX 8510-8:

switch:admin> switchstatuspolicyshow

The current overall switch status policy parameters:

Down Marginal
----------------------------------
PowerSupplies 0 0
Temperatures 0 0
Fans 1 0
WWN 0 0
CP 0 0
Blade 0 0
CoreBlade 0 0
Flash 0 0
MarginalPorts 0.00%[0] 0.00%[0]
FaultyPorts 0.00%[0] 0.00%[0]
MissingSFPs 0.00%[0] 0.00%[0]
ErrorPorts 0.00%[0] 0.00%[0]