53-1002746-01

bufOpMode

2

bufOpMode

Changes or displays the Buffer Optimized Mode.

SYNOPSIS

bufopmode --set slot [-f]

bufopmode --reset slot

bufopmode --show slot

bufopmode --showall

DESCRIPTION

Use this command to display or change the buffer optimized mode on a switch.

When buffer optimized mode is enabled on a slot, additional buffers are allocated on the internal ports.
Use this feature, if you have slow draining devices connected to the slot and there are no long distance
links or F_Port buffers configured on that slot.

You must power off the slot before changing the buffer optimized mode. Changes take effect immediately
after the slot is powered on

Enabling buffer optimized mode removes all long distance configurations or F_Port buffers on that slot.
You will be prompted if any F_Port buffers or long distance configurations are detected.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

This command is supported only on the Brocade FC8-16, FC8-32, and FC8-48 blades in a DCX or
DCX-4S chassis. An asterisk (*) next to the slot configuration status indicates an unsupported blade.
Refer to the example section for an illustration.

This command is not supported on Control Processor (CP) blades and core blades.

OPERANDS

This command has the following operands:

slot

Specifies the slot number.

--set

Enables buffer optimized mode on the specified slot. This commands prompts for
confirmation before removing any F_Port buffers or long distance configurations
on that slot. Use the -f option to execute this command without confirmation.

--reset

Clears buffer optimized mode on the specified slot.

--show

Displays the current buffer optimized mode for the specified slot (On or Off).

--showall

Displays the current buffer optimized mode for all slots. An asterisk (*) next to the
slot configuration status indicates an unsupported blade.

EXAMPLES

To display the buffer optimized mode for all slots on a DCX with supported blades:

switch:admin> bufopmode --showall
Slot 1: buffer optimized mode - Off
Slot 2: buffer optimized mode - Off
Slot 3: buffer optimized mode - Off
Slot 4: buffer optimized mode - Off