Reset storage array battery install date, Description, Syntax – Dell PowerVault MD3260i User Manual

Page 239: Parameter

Advertising
background image

Parameter

Description

errors—Statistics are reset for the most recent

20 failed resynchronization samples.

Notes

Statistics are reset for replicated virtual disks in the Primary role. The statistics that are reset include the following data:

Synchronization start time

Synchronization type (manual or periodic)

Synchronization duration

Number of bytes sent

Maximum and minimum write time (for a single write)

Maximum and minimum synchronization data rate

Total write time

Repository utilization (%)

Recovery point age

Reset Storage Array Battery Install Date

Description

This command resets the age of the batteries in a storage array to zero days. You can reset the batteries for an entire
storage array or just the battery for a specific RAID controller module or in a specific battery pack.

Syntax

reset storageArray batteryInstallDate controller=(0 | 1)

Parameter

Parameter

Description

controller

Specifies the RAID controller module that contains the
battery for which to reset the age. Valid RAID controller
module identifier values are 0 and 1. The identifier value
is 0 for the RAID controller module on the top and 1 for
the RAID controller module on the bottom when viewed
from the rear of the enclosure. Use the controller
parameter only for RAID controller modules with batteries.

NOTE: If you do not specify a RAID controller module, the age is reset for the storage array battery or both RAID
controller module batteries. If you specify a RAID controller module, then the age for only that RAID controller
module battery is reset.

239

Advertising