Rouble check – Sony CCD-TRV62 User Manual

Page 69

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

rouble check

iptom

Cause and/or Corrective Action

■ cassette cannot be
loved from the holder.

• The battery is dead.

Use a charged battery pack or the AC power adaptor,
(p. 6, 25)

md ^ indicators flash and
function except for cassette

tion works.

• Moisture condensation has occurred.

■¥ Remove the cassette and leave the camcorder for at least

1 hour. (p. 63)

‘ date or time indicator is

hing.

• You pressed DATE and TIME together for more than 2

seconds.

The camcorder is not malfunctioning. You may start
recording. Flashing will stop soon.

• The lithium battery is weak or dead.

4 Replace the lithium battery with a new one. (p. 55)

tape does not move when

ideo control button is

ssed.

• The POWER switch is set to CAMERA or OFF.

■> Set it to VTR.

• The tape has run out.

Rewind the tape or use a new one. (p. 22)

‘ Steady, Shot function does

activate.

• STEADY SHOT is set to OFF.

■* Set STEADY SHOT to ON. (p. 43)

• The Steady Shot function does not work when the wide

mode is set to 16:9 FULL.

‘ autofocusing function
'S not work.

• FOCUS is set to MANUAL.

Set it to AUTO. (p. 37)

• Shooting conditions are not suitable for autofocus.

Sef FOCUS to MANUAL to focus manually, (p. 37)

! fader function does not
rk.

• The START/STOP MODE switch is set to 5SEC or .

Set it to A . (p. 15)

• A title is displayed.

Stop superimposing the title, (p. 44)

sound or only a low

ind is heard when playing

k a tape.

• The stereo tape is played back with HiFi SOUND set to 1

or 2 in the menu system.

Set to STEREO in the menu system, (p. 31)

essive high-pitched sound

leard.

• The picture has been recorded with WIND set to ON in the

menu system.
-> When there is no wind, set it to OFF. (p. 29)

i date or time indicator
appears.

• Reset the date and time. (p. 57)

:ture

iptom

Cause and/or Corrective Action

i image on the viewfinder

ien is not clear.

• The viewfinder lens is not adjusted.

Adjust the viewfinder lens. (p. 12)

ertical band appears when

rbject such as lights or a

die flame is shof against a
k background.

• The contrast between the subject and background is too

high. The camcorder is not malfunctioning.

Change locations.

(to be continued)

>

Q.

C

l

69

Advertising
This manual is related to the following products: