Trouble check

Self-diagnosis function

If the self-diagnosis function works to prevent
the camcorder from malfunctioning, the a five­
digit serv ice number (combination of a letter
and figures) flashes in the viewfinder or on the
LCD screen. In this case, check the following
table.

HicjsasTsy

-C:21:00'

53 min. CM

First three digits

Cause and/or Corrective Action

C21

• Moisture condensation has occurred.

Remove the cassette and leave the camcorder for at least 1
hour. (p. 63)

C22

• The video heads are dirty.

Clean the heads using the Sony V8-25 CLH cleaning cassette
(not supplied), (p. 63)

C23

• The camcorder does not operate when using a battery pack that

is-not an "InfoLlTHlUM" battery pack.

Use an "InfoLlTHlUM" battery pack. (p. 6)

C31

• To prevent the camcorder from malfunctioning, the self-

diagnosis function has worked.
■> Remove the cassette and insert it again, and then operate the

camcorder, (p. 10)

C32

• To prevent the camcorder from malfunctioning, the self-

diagnosis function has worked.

Disconnect the power cord of the AC power adaptor or
remove the battery pack. After reinstalling the power source,
operate the camcorder.

E61
E62

• To prevent the camcorder from malfunctioning, the self-

diagnosis function has worked.

When you contact your Sony dealer or local authorized Sony
service facility, inform the service number with five digits,
(example: E:61:10)

If a difficulty persists after checking the problem a few times, contact your Sony dealer
or local authorized Sony service facility.