CellarPro 1800XTS-B BEER COOLING UNIT, 2176 User Manual

Page 17

Advertising
background image


- Slide the light fixture off the second mounting bracket.

10. With 7/16 socket wrench, remove the two hex head bolts that attach the cooling

unit to the ceiling of the cellar. Save these bolts! Leave mounting brackets

attached to the cooling unit so that the proper location can be duplicated with

the replacement cooling unit.

PLEASE NOTE: If the nut in the ceiling becomes loose, you will need to use

pliers from the top of the cabinet to hold the nut and keep it from spinning with

the bolt.

11. The cooling unit is now free to remove. Drop front end down, and move side to

side to free from cabinet opening.

CAUTION: Two people may be required to remove the cooling unit, which weighs

58 pounds. Do not let the cooling unit drop on unprotected bottle racks.

TO INSTALL THE REPLACEMENT COOLING UNIT

1. Carefully remove the replacement cooling unit from the packaging. NEVER store

the cooling unit upside down or on its side, and NEVER turn the unit upside down.
You may reuse this packaging for shipping or storing the old cooling unit

2. Remove any materials that have been packed inside the exhaust cavity.

3. Before installing the cooling unit, make sure it works by plugging it in and letting

it run on a hard, flat surface for no more than 5 minutes. Check that cold air is
being produced by the unit.

PLEASE NOTE:

CellarPro cooling systems are

programmed with a 3-minute delay at start-up to protect its internal
components.

4. For top-vent configurations, make sure that the exhaust panel is installed at

the REAR of the cooling unit, so that the top of the unit has an opening for the
hot air exhaust. For rear-vent configurations, make sure that the exhaust panel
is installed in the TOP of the cooling unit, so that the rear of the unit has an
opening for the hot air exhaust. In both configurations, return air from outside
the cellar will come into the coils at the rear of the cooling unit.

5. If using mounting clips, attach the clips to the FRONT of the cooling unit so that the

short side slides under the metal fold near the top of the cooling unit, and space the
clips so that they’ll line up with the holes in the ceiling of the cellar. You may need to
remove the front grill (attached with two screws on each side of the cooling unit) in
order to slide the mounting clips under the sheet metal, then replace the front grill
after the clips are in place.