Standard Protection Mechanisms


The cooling unit is programmed to shut down certain components to protect those
components, as well as the wine inside the cellar, under the following circumstances:

Scenario

What it means

What happens

P1 Alarm

Probe 1, which senses
the temperature inside
the cellar and controls
the on/off cycles of the
cooling unit, has failed

The cooling unit enters a timed
auto-cycle mode until Probe 1 is
repaired or replaced. In this mode,
the cooling unit will turn for 12
minutes and off for 8 minutes.

Optional Protection Mechanisms

CellarPro cooling systems can be programmed to turn off the compressor and
condenser fan in the event of an HA2 alarm, as described below. If you’d like to turn on
this protection mechanism, please call us toll-free at 877.726.8496

P3 > 140°F for more
than 2 hours

The condenser probe is
measuring
temperatures that are
too hot

The compressor and condenser fan
will turn off until the condenser
temperature falls below 140°F

Maintenance

The condenser coils at the back of the cooling unit
will collect dust, dirt and lint over time. It is critically
important to clean the coils periodically. If the
condenser coils become clogged, the cooling unit
will not have proper airflow and its performance
and longevity will be compromised.

To clean the coils, simply vacuum or brush the coils
until all dust and lint have been removed. Do not
use compressed air to clean the coils because it may force dirt particles into the cooling
system and cause serious damage to its internal components.