Advanced Operation

CellarPro cooling systems can be programmed with advanced settings to

achieve more control over conditions inside the cellar. Conditions like

humidity, the Temperature Differential, and alarm settings all can be modified

for custom applications. To access the advanced settings, do the following:

Press the “Set” button and the “Down” button together at the same time,

and hold for three seconds. Then, use the “Up” or “Down” button to scroll

to the following screen:

HUMIDITY: The factory preset for this setting is “3”.
If the humidity inside the cellar is too low, press the “Set”

button, then use the “Up” button until the desired setting is

reached. The recommended range for this setting is 0-6.

TEMPERATURE DIFFERENTIAL: The factory preset for this setting

is “4” without a bottle probe, and “1” with a probe.
When added to the set point, this setting determines the

temperature at which the cooling unit will cycle on. The

recommended range for this setting is 4 or 5 unless using a

bottle probe

in liquid

, in which case the recommended

setting is 1.

HIGH TEMPERATURE ALARM: The factory preset for this

setting is “70”.
This setting designates the High temperature inside the cellar

at which the alarm is triggered. We recommend leaving

this setting at the factory preset.

LOW TEMPERATURE ALARM: The factory preset for this setting

is “45”.
This setting designates the Low temperature inside the cellar

at which the alarm is triggered. We recommend leaving

this setting at the factory preset.

ENERGY SAVINGS MODE DIFFERENTIAL: The factory preset

for this setting is “4”.
This setting increases or decreases the Temperature

Differential for the Energy Savings Mode. The

recommended range for this setting is 2-4.