Advanced Operation
CellarPro cooling systems can be programmed with advanced settings to
achieve more control over conditions inside the cellar. Conditions like
humidity, the Temperature Differential, and alarm settings all can be modified
for custom applications. To access the advanced settings, do the following:
•
Press the “Set” button and the “Down” button together at the same time,
and hold for three seconds. Then, use the “Up” or “Down” button to scroll
to the following screen:
HUMIDITY: The factory preset for this setting is “3”.
If the humidity inside the cellar is too low, press the “Set”
button, then use the “Up” button until the desired setting is
reached. The recommended range for this setting is 0-6.
TEMPERATURE DIFFERENTIAL: The factory preset for this setting
is “4” without a bottle probe, and “1” with a probe.
When added to the set point, this setting determines the
temperature at which the cooling unit will cycle on. The
recommended range for this setting is 4 or 5 unless using a
bottle probe
in liquid
, in which case the recommended
setting is 1.
HIGH TEMPERATURE ALARM: The factory preset for this
setting is “70”.
This setting designates the High temperature inside the cellar
at which the alarm is triggered. We recommend leaving
this setting at the factory preset.
LOW TEMPERATURE ALARM: The factory preset for this setting
is “45”.
This setting designates the Low temperature inside the cellar
at which the alarm is triggered. We recommend leaving
this setting at the factory preset.
ENERGY SAVINGS MODE DIFFERENTIAL: The factory preset
for this setting is “4”.
This setting increases or decreases the Temperature
Differential for the Energy Savings Mode. The
recommended range for this setting is 2-4.