Size & Electrical Specifications

Model

Dimensions
W” x D” x H”

Weight

(lbs)

Operating

Amps

Required

Circuit

1800 QTL/QT/XT/XTS

18 x 16.5 x
10.5

60

3

15-Amp

Dedicated

1800 XTSx

18.1 x 22 x
10.6

70

3

15-Amp

Dedicated

Ambient Environment

CellarPro cooling units are designed to operate in ambient temperatures between 45°F
and 95°F. Except for the 1800XTSx cooling unit, all cooling units are designed for
internal use only, and are not designed for exposure to the exterior.

CellarPro cooling units are not designed to generate heat inside the cellar, so if
temperatures inside the cellar drop below proper wine storage temperatures, the
cooling unit cannot increase the temperature inside the cellar.

Proper temperatures are maintained by transferring heat from inside wine cellars and
exhausting heat through the top (top-vent) or rear (rear-vent) of the cooling units.

Insulation

CellarPro cooling units are designed to be installed inside wine cellars that have proper
insulation, moisture barriers and an airtight seal from the environment outside the
cellar.

Interior walls and floor
should have a minimum of
R-11 insulation, and a vapor
barrier on the warm side of
the insulation. The ceiling
should have a minimum of
R-19 insulation and a vapor
barrier on the warm side of
the insulation. Doors also
should be insulated and
tightly sealed with weather
stripping around the
perimeter of the door.

Surface-mounted fixtures
are recommended over

V9.14

6

Advertising