6. If your wine cabinet has three pieces of foam located on the bottom and on each

side of the black metal bracket that supports the rear of the cooling unit (attached to
the rear wall in most top-vented units), place these foam pieces along the bottom
and sides of the metal bracket.

7. Install the cooling unit by following the removal instructions described above in

reverse.

8. A complete and proper seal must be made between the cellar and the cooling unit to

ensure that outside air does not enter the cellar. Use butyl adhesive tape to seal the
perimeter where the cooling unit touches the cellar by rolling the tape with your
fingers into a thin (pencil diameter) "rope", then press the tape into the cracks where
the cooling unit touches the cellar.

9. Check the seal by having a helper stand in front of the cabinet while you shine a

flashlight around the cooling unit edges to discover any gaps in sealant.

10. Wait 24-hours before running the cooling unit. We recommend plugging the cooling

unit into an outlet with a dedicated 15-amp circuit and a surge protector.

RETURNING THE ORIGINAL COOLING UNIT:

If the original cooling unit is under warranty and you are returning it, please follow the
instructions below:

1. Use the original packaging to repack the cooling unit.

2. Make sure that the cooling unit is upright in the box

3. The exterior of the box should be prominently marked with “This Side Up” and

“Fragile” for the freight carrier