Lighting controls – Code 3 RLS User Manual

Page 13

Advertising
background image

1 3

WAIL - This mode produces the Wail tone. Depressing the MANUAL button will now produce Manual wail tone
and ramp up until released. Depressing the AIR HORN button will produce the Air Horn sound. The siren can be
scrolled in this position as described above. The Remote/Horn Ring input will also activate the Interclear output
for approximately 60 seconds.

YELP - This mode produces the Yelp tone. Pushing the MANUAL button will now produce the Manual wail tone
and ramp up until released. If the AIRHORN button is pushed, the Airhorn sound will be produced. The siren can
be scrolled from this position as described above. The Remote/Horn Ring input will also activate the Interclear
output for approximately 60 seconds.

HI-LO - This position produces the Hi-Lo tone. Pushing the MANUAL button will produce the Manual Wail tone
until released. If the AIRHORN button is pushed, the Airhorn sound will be produced and when released the
siren return to Hi-Lo.The siren cannot be scrolled from this position. The Remote/Horn Ring input will activate
the Interclear output and cause the tone to change to HyperLo for approximately 60 seconds.

Push-to-Talk (PTT) Microphone Switch - Keying the microphone will automatically override whatever mode the
siren is in and broadcast public address messages over the siren speaker.

MANUAL Pushbutton Momentary Switch - Produces the Manual tone as described above.

AIR HORN Pushbutton Momentary Switch - Produces the Air Horn tone as described above.

MANUAL / AIRHORN SWITCH - The MANUAL / AIRHORN slide switch located on the front of the siren
amplifier, Figure 5, selects the function for the REMOTE (external switch) circuitry when the siren is in standby
mode. When the the siren is in standby mode and switch is to the right, the Horn Ring circuitry remotely
"depresses" the AIR HORN button and it produces the effects outlined above. When the slide switch is to the
left, it allows the REMOTE circuitry to remotely "depress" the MANUAL pushbutton. When in the "Scroll "
mode this switch has no effect unless in STANDBY position.

LED STATUS INDICATOR - The green LED status indicator indicates the the siren amplifier is on when lighted;
off or standby mode when unlighted.

-Lighting Controls-

WARNING LIGHTS 3 LEVEL PROGRESSIVE SLIDE SWITCH:

POSITION 1 - Supplies power to Lighting Level 1. Illuminates Green LED. Activates LightAlert if supplied

POSITON 2 - Supplies power to Lighting Levels 1 & 2. Illuminates Green and Yellow LED's. Activates
LightAlert and SirenLock options if supplied.

Position 3- Supplies power to Lighting Levels 1,2, & 3. Illuminates Green, Yellow, AND Red LED's. Activates
LightAlert and SirenLock if supplied.

Auxiliary Switches:

AUXILIARY SWITCH "A" - Supplies power to the load connected to terminal SW A.

AUXILIARY SWITCH "B" - Supplies power to the load connected to terminal SW B.

AUXILIARY SWITCH "C" - Operates circuit connected to terminals SWC NO, SWC NC, SWC COM.
Functions as a momentary activation, 10 sec. timed switch or as a latching switch. The timed output function
may be enabled/disabled by the two position switch located on the rear of the siren control head.

AUXILIARY SWITCH "D" - Supplies power to the load connected to terminal SW D.

Advertising