Terminal Plugs - Rear Panel-

(See Wiring Diagram page 16)

I M P O R T A N T !

Remember auxiliary outputs A,B,D,E,F can supply a maximum of 20 Amps each for a
combined total of 30 Amps. Install appropriate fuses in each output wire as close to the siren
as possible.

SW A - Connect to the load to be controlled by Auxiliary Switch "A".

SW B - Connect to the load to be controlled by Auxiliary Switch "B".

SW C NO - Connect to the load to be controlled by the normally-open contact on Auxiliary Switch "C".

SW C NC - Connect to the load to be controlled by the normally-closed contact on Auxiliary Switch
" C " .

SW C COM - Common or power feed for Auxiliary Switch "C". Terminals are a SPDT circuit that
may be connected as latching (Push-On/Push-Off) or timed momentary circuit. This terminal may
also be connected to the vehicle's ignition circuit for added security when used with electric gun
locks. A switch accessible through the back of the siren control head allows the 10 second timed
output feature to be disabled thus making this switch operate as a Push-On/Push-Off function.
This circuit will handle up to 10 Amps, and should be protected with a fuse at the supply source.

SW D - Connect to the load to be controlled by Auxiliary Switch "D"
.
SW E - Connect to the load to be controlled by Auxiliary Switch "E".

SW F - Connect to the load to be controlled by Auxiliary Switch "F".

HORN RING - Connect to the wire coming from the vehicle horn switch at the steering wheel.

HORN - Connect to the vehicle horn or vehicle horn ring relay.

REMTE - Connect to the Remote terminal on the Siren Amplifier Connector.

#8 GAUGE RED WIRE PIGTAIL - provides power to the 3-Level, progressive lighting outputs only.
The wire can be ordered with an optional connector to allow for convenient removal. The
connector should be soldered to each wire, NOT crimped. This connection is designed to provide
50 amp service and therefore nothing smaller than #8 gauge wire should be connected to it. The
circuit breaker used should be sized for the actual load of the lighting used and located as close to
the battery positive as possible.

4 POSITION SCREW-TYPE TERMINAL BLOCK CONNECTOR

+12VAUX - Connect to the positive terminal of the battery with 30 Amp circuit protection. Locate the
fuse or circuit breaker at the battery and use #10 gauge wire minimum. This terminal provides output
power for switches A,B,D,E & F and must be connected whether these auxiliary outputs are used
or not.

I M P O R T A N T !

The Level 1-3 outputs can supply a maximum of 30 Amps each for a combined total of 50
Amps. Install appropriate fuses in each output wire as close to the siren as possible.

LEVEL 1 - Connect to the first level of warning lights (Green LED) position "1" on level switch.

LEVEL 2 - Connect to the second level of warning lights (Yellow LED) position "2" on level switch.

LEVEL 3 - Connect to the third level of warning lights (Red LED) position "3" on level switch.