Code 3 RLS User Manual

Page 20

Advertising
background image

2 0

Lighting Section

Warning Light Control:Progressive switching, 3 levels

50 Amps. maximum combined total to #8 wire
Audible alarm (optional).

Level 1

30A maximum
Green LED Indication

Level 2

30A maximum
Yellow LED Indication

Level 3

30A maximum
Red LED indication.

Auxiliary Control - SPST ( Aux. Switches A, B, E, D, F )

Accessory Switch operation - Push-on/off operation.
Independent circuits - 5
30 Amps. maximum combined total
20 Amps. maximum load for any single output A,B,E,D or F
LED indication.
Audible alarm

Auxiliary Control - SPDT (Aux. Switch "C"):

Accessory Switch operation -Momentary (switch located on rear of siren control)
Independent circuits - 1
10 Amps. maximum connected load.
LED indication.
Audible alarm
Timed Output

Horn Transfer Relay - SPDT:

Activated in Level 2 and 3.
10 Amps. maximum connected load.

System - Weight:

Amplifier

4.25 lbs (1.9 Kg)

Control Unit

0.5 lbs (.226 Kg)

Microphone &
Hardware

2.0 lbs (.9 Kg)

Size: Amplifier -

7.5" L x 7.5" W x 3.25" H

Control Unit - 7" L x 3.5" H x 1.5" D

Temperature: -22°F - +149°F (-30°C - +65°C) SAE Equipment Type EVS1