Diagnostic Function

RLS Siren Models 3997 & 3999 features a "walk-around" diagnostic test function. The user may invoke this
function by holding the "Air Horn" switch while turning on the vehicle's ignition switch. When the "Air Horn"
switch is released the siren will begin a timing sequence which will turn on each control output for about two
seconds. Each output, including the Arrow Stik (in Flash mode) and the siren tones will be cycled during this
sequence. The siren tones will not be heard if the Park-Kill feature is being used and the vehicle is in Park.
This timed feature enables the user to start the diagnostic function, exit the vehicle and observe a brief test can
be interrupted by cycling the vehicle's ignition switch off. After the test, the vehicle's ignition power must be
cycled off and back on to insure that everything is restored to the normal standby mode.

O p t i o n s

Lighting Switch Connector- Connectors which when soldered to the #8 wire and the user supplied power
wire offers quick disconnect service.

Microphone Extension Cable- A twenty (20) ft. microphone extension cable. Allows the siren amplifier to be
mounted up to twenty feet from the driver's area.

NIGHTPROBE

TM

Spotlight Control Module - Allows use of the RLS 3999 Siren Control to provide full control

of the NIGHTPROBE

TM

spotlight with linear acceleration from stop to full speed.

Auxiliary Relay Module - Provides eight (8) additional switched +12VDC outputs at up to 10A each, limited to
a maximum total combined current of 60A.

S p e c i f i c a t i o n s

Siren Section

Input Voltage - 10 to 16 VDC, negative ground (earth) - 12V units
(Note: Operation of 12V units above 15 VDC for an extended period of time may result in speaker damage.)

20 to 30 VDC, negative ground (earth) - 24V units

(Note: Operation of 24V units above 30 VDC for an extended period of time may result in speaker damage.)

Operating Current 100W: 8 Amps @ 13.6V with 11-ohm load ( 100 W Spkr ) - 12Vunits

4. 5 Amps @ 27.6V with 11-ohm load ( 100 W Spkr ) - 24Vunits

200W:
14 Amps @ 13.6V with 5.5-ohm load ( 2- 100 W Spkr ) - 12V units

9 Amps @ 27.6V with 5.5-ohm load ( 2- 100 W Spkr ) - 24V units

Note: There is no 58 Watt speaker connection available.

Standby Current: 25 mA excluding backlighting

Cycle Rate:

WAIL - 11 cycles/minute.
YELP - 200 cycles/minute.

Voltage Output ( approx. ) 64 V peak-to-peak

Audio Section

Audio Response:

3 dB down points - 500 to 3000 hz.
1000 hz. 0 dB Reference

Audio Distortion:

10% or less below clipping.