Connecting the primary inductive pickup, Connecting the primary inductive pickup -7 – Dynojet 224: Eddy Current Brake User Manual

Page 53

Advertising
background image

B A S I C D Y N A M O M E T E R O P E R A T I O N

Connecting The RPM Pickup

Version 3

Model 224 Above Ground Eddy Current Brake Installation and User Guide

3-7

C

ONNECTING

T

HE

P

RIMARY

I

NDUCTIVE

P

ICKUP

The primary inductive pickup cannot be in contact with, or it’s connecting wire be
crossing, other engine electrical wires or stray RF interference may result.
1

Clip the primary inductive pickup around the primary side of the coil.

2

Route the primary wire cable clear of devices that produce electronic noise.
Note: You must ground the vehicle to the dyno for the electronics to function
properly.

Figure 3-5: Primary Inductive Pickup

connect primary

inductive pickup on the

negative side of the coil

coil

Advertising