Cp384, Configuration cp384, Con2 – Kontron CP384 User Manual
Page 53
Advertising
ID 31440, Rev. 01
Kontron Modular Computers GmbH
P R E L I M I N A R Y
Rev
N
r. = CP384 -
31440_
01 - 060
503/
144
230
Page 4 - 7
Configuration
CP384
Figure 4-7: External Reset Connection
Note ...
The voltage source for the cluster is an external supply in the range 24V DC ±
20%, and it supplies only the power to drive the relay control circuits, but not the
output channels themselves.
The channel output pins are galvanically isolated from the VCC within the
CP384 board.
Ch 0
Ch 7
CP384
CON2
+
External
VCC
EXTGND
V
External GND
0
7
Supply Voltage
R
Reset
VCC
{
digital output
channels