vNr. = CP384

-

31440

_01 -

06

0503

/14

4233

Page 4 - 16

Configuration

CP384

Table 4-22: ROM Control Register

BITS

TYPE

DEFAULT

FUNCTION

31-19

r/w

0

Reserved

17-16

r/w

00

Opcode

15-8

r/w

00

Reserved

8-0

r/w

00

Internal address (A8 ... A0)

Note ...
The commands READ, EWEN (Write Enable) and WRITE are sufficient for all
purposes.

Table 4-23: Opcodes and Commands

OPCODE

A8 ... A0

COMMAND

00

11xxxxxxx

EWEN

10

xxxxxxxxx

READ

01

xxxxxxxxx

WRITE

Note ...
The EWEN (Erase and Write Enable) command must be executed once before
the first write.

Table 4-24: ROM Status Register

BITS

TYPE

DEFAULT

FUNCTION

31

r/w

0

Busy/Ready

30-0

r/w

00

Reserved

Note ...
As soon as the Startbit is set the Busy/Ready bit becomes active (Busy=1). It
remains set as long as the command is executed and is reset when command
execution is complete.

Table 4-25: ROM Data Register

BITS

TYPE

DEFAULT

FUNCTION

31-8

r/w

0

Reserved

7-0

r/w

0

Data (for data read and write commands)