5 applied standards, 1 ce compliance, 2 mechanical compliance – Kontron VSBC-32 User Manual

Page 30: 3 environmental tests, Applied standards - 14, Ce compliance - 14, Mechanical compliance - 14, Environmental tests - 14, Vsbc-32 introduction

Advertising
background image

VSBC-32

Introduction

ID 21168, Rev. 04

Page 1 - 14

©

PEP Modular Computers GmbH

1.5 Applied Standards

1.5.1

CE Compliance

The

PEP Modular Computers’ VMEbus and (e)CXC systems comply with the require-

ments of the following CE-relevant standards:

Emission

EN50081-1

Immission

EN50082-2

Electrical Safety

EN60950

1.5.2

Mechanical Compliance

Mechanical Dimensions

IEEE 1101.10

1.5.3

Environmental Tests

Vibration

IEC68-2-6

Permanent Shock

IEC68-2-29

Single Shock

IEC68-2-27

Power Consumption

VSBC-32:

typ. 3.0W

VSBC-32E:

typ. 3.5W

Temperature Ranges

Operation:
0° C to 70° C

(standard)

-40° C to +85° C

(extended)

Storage:
-55° C to +125° C

Humidity

0..95%, non-condensing

Dimensions

4HP/3U Eurocard (100mm x 160mm)

Weight

Mainboard:

130g

Serial interface piggyback:

20..30g

Memory piggyback:

30g

Table 1-2: VSBC-32(E) Technical Specification (Sheet 3 of 3)

VSBC-32(E)

Specification

Advertising