2 solder jumpers, Solder jumpers - 4, Vsbc-32 configuration – Kontron VSBC-32 User Manual

Page 64

Advertising
background image

VSBC-32

Configuration

ID 21168, Rev. 04

Page 4 - 4

©

PEP Modular Computers GmbH

4.1.2

Solder Jumpers

The following parameters are selected via solder jumpers:

CPU/bus clock frequency (J1/J2/J3)

Communications clock frequency (J4)

Serial EEPROM write protection (J5)

Connection of protective and signal Ground (J6)

CXC interface connector pin A5 function assignment (J11)

SRAM size (J7/J8)

Default settings are in italics.

Warning!

All solder jumpers are factory set. Alteration of their settings can
result in damage to the board. Therefore, customers must not
alter the settings of these jumpers.

Table 4-3: CPU/Bus Clock Frequency Selection

J3

J2

J1

Description

Closed

Closed

Open

25MHz

(VSBC-32 and VSBC-32E)

Open

Closed

Open

33.3MHz

(VSBC-32E only)

Table 4-4: Clock Frequencies, EEPROM Write Protection and GND Connection

Jumper

Settings

Description

J4

Open

24MHz communications clock not connected to MC68(EN)360

Closed

24MHz communications clock connected to MC68(EN)360

Note: This jumper must be set to open if the RCLK2 signal
(CXM pin C16) is required.

J5

Open

EEPROM write protection disabled

Closed

EEPROM write protection enabled

J6

Open

Signal GND not connected to Protective GND

Closed

Signal GND connected to Protective GND

Note: If this jumper is set, care must be taken to avoid any
grounding currents.

Table 4-5: SRAM Size Selection

J7

J8

Description

1-2

1-2

1MB

(VSBC-32E only)

1-3

1-3

256kB

(VSBC-32 and VSBC-32E)