B.8 jumper setting, Vmp3 vmp1-io1 module – Kontron VMP3 User Manual

Page 147

Advertising
background image

VMP3

VMP1-IO1 Module

ID 29230, Rev. 01

© 2005 Kontron Modular Computers GmbH

Page B - 11

29230

.01.UG.VC.050727/091443

P R E L I M I N A R Y

B.8

Jumper Setting

The jumper settings of the IO1 module depend on the module’s position relative to the VMP3
and other modules, if any.

Table B-4: IO1 Jumper Settings for Different Module Positions

IDSEL

Clock

GNT#

REQ#

J12

J11

J10

J1

J2

J3

J4

J5

J6

J7

J8

J9

Position 1

Set

Open

Open

Set

Open

Open

Set

Open

Open

Set

Open

Open

Position 2

Open

Set

Open

Open

Set

Open

Open

Set

Open

Open

Set

Open

Position 3

Open

open

Set

Open

Open

Set

Open

Open

Set

Open

Open

Set

Note:

Position 1 refers to the settings applicable when 1 module (IO1 or other) is
attached to the VMP3.

Position 2 refers to the settings applicable when 2 modules (IO1 or other) are
attached to the VMP3.

Position 3 refers to the settings applicable when 3 modules (IO1 or other) are
attached to the VMP3.

Important!:

Position 3 has not yet been tested and approved and is not recommended for
use with this issue of the manual.

Advertising