Watchdog control register - 10, Configuration vmp3 – Kontron VMP3 User Manual

Page 70

Advertising
background image

Configuration

VMP3

Page 4 - 10

© 2005 Kontron Modular Computers GmbH

ID 29230, Rev. 01

29230

.01.UG.VC.050727/091435

P R E L I M I N A R Y

other modes the WTE bit is available for application use.

Refer to Appendix A for further information regarding the Watchdog functional logic.

Table 4-9: Watchdog Control Register

REGISTER NAME

WATCHDOG CONTROL

ACCESS

ADDRESS

0xFFFF A008

R

W

BIT POSITION

MSB

7

6

5

4

3

2

1

0

LSB

CONTENT

WTE

WDM1

WDM0

WEN/WTR

WTM3

WTM2

WTM1

WTM0

DEFAULT

0

0

0

0

0

0

0

0

BIT CONTENT STATE

DESCRIPTION

0

WTM0

0

Watchdog timeout time:
Settings: WTM3 WTM2 WTM1 WTM0

0

0

0

0

125 ms

0

0

0

1

250 ms

0

0

1

0

500 ms

0

0

1

1

1 s

0

1

0

0

2 s

0

1

0

1

4 s

0

1

1

0

8 s

0

1

1

1

16 s

1

0

0

0

32 s

1

0

0

1

64 s

1

0

1

0

128 s

1

0

1

1

256 s

1

1

0

0

reserved

1

1

0

1

reserved

1

1

1

0

reserved

1

1

1

1

reserved

1

1

WTM1

0

1

2

WTM2

0

1

3

WTM3

0

1

4

WEN/WTR

0

Indicates that the Watchdog timer has not been enabled.

Prior to the Watchdog being enabled, this bit is known as WEN. After the
Watchdog is enabled, it is known as WTR. Once the Watchdog timer has
been enabled, this bit cannot be reset to 0. As long as the Watchdog timer
is enabled it will indicate a 1.

1

Indicates that the Watchdog timer is enabled.

Writing a ’1’ to this bit causes the Watchdog to be retriggered to the timer
value indicated by bits WTM[3:0].

5

WMD0

0

Watchdog mode:
Settings: WMD1 WMD0

Mode

0

0

Timer only

0

1

Reset

1

0

Interrupt

1

1

Dual Stage

1

6

WMD1

0

1

7

WTE

0

Indicates that the Watchdog timer has not expired.

1

Indicates that the Watchdog timer has expired.

Writing a ’1’ to this bit resets it to 0.

Advertising