IPMI Setup

2.1

IPMI in a Compact PCI Chassis

Kontron's IPMI implementation in the CompactPCI environment is compliant with the PICMG
2.9 R1.0 specification. This specification defines the pinout of the J1 and J2 CompactPCI con-
nectors as well as the addressing scheme. There should be only one BMC in the chassis, or at
least on the IPMB segment. The BMC may reside either on an CP6002, or on an external sys-
tem management card, or in a shelf management controller (ShMC). The specification allows
all of these variants. As a BMC in the system slot, the CP6002 supports dual-ported IPMB
(IPMB-0 to the SMCs and IPMB-1 to the external segments via the CompactPCI backplane
connector in accordance with PICMG 2.9).

To use the IPMI resources in a rack requires an initial setup for IPMI operation. The following
actions must first be performed to achieve operable IPMI functionality.

2.2

IPMI Setup for the CP6002

Initially the default configuration for the IPMI Management Controller of the CP6002 is:

• IRQ = none

• MODE = SMC

• IPMB = single-ported.

If this is the required configuration, no further action is required. If the configuration must be
modified, either the uEFI shell command “kipmi” or one of the open tools “ipmitool” or “ipmicmd”
may be used to modify the configuration as required.

BMC

IPMB

Address

Fix: 20h

Backplane

SMC

IPMB

Address:

B0h

(1)

SMC

IPMB

Address:

B2h

(1)

SMC

IPMB

Address:

B4h

(1)

SMC

IPMB address for SMC is determined via the location of the slot in the chassis

IPMB

Address:

B6h

SMC

IPMB

Address:

B8h

(1)

(1)

SMC

IPMB

Address:

BAh

(1)

SMC

IPMB

Address:

BCh

(1)

IPMB 0

IPMB 0

(1)

IPMB 1