Cp6002 ipmi firmware user guide – Kontron CP6002 IPMI User Manual

Page 33

Advertising
background image

CP6002

IPMI Firmware User Guide

ID: 1039-1613, Rev. 2.0

Page 33

1Fh /
NNN:IPMC Storage

Management Subsystem
Health (28h) /
Sensor-specific (6Fh)

0002h / 0000h /
0003h

IPMI controller storage
access error

Y

/ 0002h

20h /
NNN:IpmC Reboot

Platform Alert (24h) /
‘digital’ Discrete (03h)

0002h / 0000h /
0003h

2 = Management controller
is (re-)booting

N

21h /
NNN:SEL State

Event Logging Disabled (10h)
/
Sensor-specific (6Fh)

003Ch / 0000h /
003Ch

State of event logging

N

22h /
NNN:IPMI Info-1

OEM Firmware Info 1 (C0h) /
OEM (70h)

0003h / 0000h /
7FFFh

For internal use only

N

23h /
NNN:IPMI Info-2

OEM Firmware Info 2 (C0h) /
OEM (71h)

0003h / 0000h /
7FFFh

For internal use only

N

24h /
NNN:IniAgent Err

Initialization Agent (C2h) /
‘digital’ Discrete (03h)

0002h / 0000h /
0003h

Initialization Agent error
status. Used on BMC only.
1 = error free

N

25h /
NNN:Board Rev

OEM Board Revision (CEh)/
Sensor-specific (6Fh)

0000h / 0000h /
7FFFh

Board revision information

N

Table 9:

Sensor List

SENSOR Number

/

ID string

SENSOR TYPE (CODE) /

EVENT/READING TYPE

(CODE)

Ass. Mask /

Deass. Mask /

Reading Mask

DESCRIPTION

LED I1on

error /

Reading

Mask

Advertising