Sensors implemented on the cp6002, 1 sensor list, Sensor list – Kontron CP6002 IPMI User Manual

Page 31: Cp6002 ipmi firmware user guide

Advertising
background image

CP6002

IPMI Firmware User Guide

ID: 1039-1613, Rev. 2.0

Page 31

11.

Sensors Implemented on the CP6002

The sensor name (ID string) has a name prefix which is ‘NNN:’ in the lists below. When reading
the sensor name after module insertion this prefix becomes automatically adapted to the role
(BMC or SMC) and the physical position (slot number) of the module in a rack. If the module's
Management Controller is set up as a BMC the prefix will be ‘BMC:’ independent of the slot
where it resides. If the module's Management Controller is set up as a SMC the prefix will be
‘Sxx:’ where xx is the slot number (e.g. 09).

The sensor number is the number which identifies the sensor e.g. when using the IPMI com-
mand ‘Get Sensor Reading’. Please note that ‘ipmitool’ accepts sensor numbers in decimal
(e.g. ‘10’) or hexadecimal (e.g. ‘0xa’) notation.

The IPMI tool ‘ipmitool’ displays for the command ‘ipmitool sdr list’ the contents of the sensor
data record repository (SDRR) of the whole rack if the SDRR has been generated. The gener-
ation of the SDRR has always to be redone after adding or removing a board from the rack.
Refer to chapter 2.3, IPMI Setup for the Rack for further information.

11.1

Sensor List

For OEM (Kontron) specific sensor types and codes in the following table please refer to chap-
ter 11.3.
Table 9:

Sensor List

SENSOR Number

/

ID string

SENSOR TYPE (CODE) /

EVENT/READING TYPE

(CODE)

Ass. Mask /

Deass. Mask /

Reading Mask

DESCRIPTION

LED I1on

error /

Reading

Mask

0h /
NNN:Hot Swap

ATCA/CTCA Hot Swap (F0h) /
Sensor-specific (6Fh)

001Fh / 0000h /
001Fh

Hot swap sensor

N

1h /
NNN:Temp CPU

Temperature (01h) /
Threshold (01h)

1A81h / 7A81h /
3939h

CPU die temperature

Y

/ 0F3Ch

2h /
NNN:Temp PCH

Temperature (01h) /
Threshold (01h)

0A80h / 7A80h /
3838h

Temp Chipset

Y

/ 0F3Ch

3h /
NNN:Temp Graphic

Temperature (01h) /
Threshold (01h)

1A81h / 7A81h /
3939h

Temp Graphic

Y

/ 0F3Ch

4h /
NNN:Temp Board 1

Temperature (01h) /
Threshold (01h)

7A95h / 7A95h /
3F3Fh

Temp Board 1

Y

/ 0F3Ch

5h /
NNN:Pwr Good

Power supply (08h) /
OEM (73h)

0000h / 0000h /
400Fh

Status of all power lines

N

6h /
NNN:Pwr Good Evt

Power supply (08h) /
OEM (73h)

0180h / 7180h /
3838h

Power fail events for all
power lines

Y

/ 402Fh

7h /
NNN:Board 3.3V

Voltage (02h) /
Threshold ( 01h)

2204h / 2204h /
1212h

Board 3.3V supply

Y

/ 0F3Ch

8h /
NNN:Board 5VIPMI

Voltage (02h) /
Threshold ( 01h)

2204h / 2204h /
1212h

Management Power (MP)
5V

Y

/ 0F3Ch

9h /
NNN:Board 5.0V

Voltage (02h) /
Threshold (01h)

2204h / 2204h /
1212h

Board 5V supply

Y

/ 0F3Ch

Ah /
NNN:Board 12V

Voltage (02h) /
Threshold (01h)

2204h / 2204h /
1212h

Board 12V supply

Y

/ 0F3Ch

Advertising