Fru data, 1 structure and functionality, Ipmi firmware user guide cp6002 – Kontron CP6002 IPMI User Manual

Page 36

Advertising
background image

IPMI Firmware User Guide

CP6002

Page 36

ID: 1039-1613, Rev. 2.0

12.

FRU Data

12.1

Structure and Functionality

The Management Controller provides 4 kB non-volatile storage space for FRU information.

Please refer to Related Publications: IPMI- Platform Management FRU Information Storage
Definition v1.0, Document Revision 1.1 which defines the structure of FRU data.

Full low-level access to read or write a module's FRU Information is provided by regular IPMI
FRU Device commands. Care must be taken when writing FRU information directly using stan-
dard IPMI commands because there is no write protection. Invalid FRU information may disturb
a shelf management software which uses the FRU data.

To avoid this situation there is a Kontron Linux tool 'frum', which permits displaying and partial
modification of FRU data. For example, the 'frum' tool makes it easy to modify Product Info
Area fields like Product Version or Product Serial Number.

e.g. for
Power Good /
Power Good Event

73h

Sensor-specific
Offset

Event

0h

HS fault#

1h

HS early fault#

2h

DEG#

3h

FAL#

4h

n.a.

5h

n.a.

6h

n.a.

7h

n.a.

8h

n.a.

9h

n.a.

Ah

n.a.

Bh

n.a.

Ch

n.a.

Dh

n.a.

Eh

vccMainGood

Board revision (CEh)

6Fh
(sensor type specific)

Bits [7:0] = Board Revision number
This corresponds to Board and PLD Revision register
described in CP6002 board manual.

Table 12: OEM Event/Reading Types

OEM

SENSOR

TYPE (CODE)

OEM

EVENT/READING

TYPE (CODE)

DESCRIPTION

Advertising