10.2

Set Firmware Parameters

This command permits the selection of interrupts to be used during KCS communication.

Please note that parameters which are set while the board is write protected are only valid until
the next IPMI firmware reset.
Table 6:

Set Firmware Parameters

COMMAND

LUN

NetFn

CMD

Set Firmware Parameters

03h

OEM = 3Eh

05h

REQUEST DATA

Byte

Data Field

1

Reserved
B4h

2

Reserved
90h

3

Reserved
91h

4

Reserved
8Bh

5

Cmd Flags
[6:2] Reserved
[1] 0b = get only, 1b = set parameters
[0] 0b = do not reset,
1b = reset Management Controller after setting
parameters

6

Operating Modes
[7:5] Reserved
[4] 0b = IPMB dual-ported, 1b = IPMB single-ported (default)
[3:1] Reserved
[0] 0b = BMC, 1b = SMC

7

IRQ number
FFh = do not use interrupts
0Ah = use IRQ10
0Bh = use IRQ11
Any other values = Reserved