4

IPMBL State

C3h
(OEM Kontron)

6Fh
(Sensor Specific)

For additional

information, refer to

section Kontron

IPMB-L Link

Offset 2: IPMB-L disabled
Offset 3: IPMB-L enabled

5

MMC Stor Err

28h
(Management

Subsystem

Health)

6Fh
(Sensor Specific)

Generates an event

when a local EEPROM

storage error is

detected.

Offset 1: Controller access

degraded or unavailable
See IPMI v1.5 table 36.3,

Sensor type code 28h for

sensor definition

6

MMC Reboot

24h
(Platform Alert)

03h
(Digital Discrete)

Generates an event

when MMC reboot is

detected.

Offset 0: State Deasserted
Offset 1: State Asserted

7

MMC FWUP

C7h
(Kontron OEM MC

Firmware Upgrade

Status)

6Fh
(Sensor Specific)

Generates events

after IPMI Firmware

upgrade process is

finished

Offset 0: Firmware upgrade in

progress (no event)
Offset 1: Firmware upgrade

succeeded

8

MMC Ver Chg

2Bh
(Version Change)

6Fh
(Sensor Specific)

Generates an event

when the IPMI FW

changes

Offset 1: Firmware / Software

change detected
See IPMI v1.5 table 36.3,

Sensor type code 2Bh (Version

Change) for sensor definition

9

FPGA Ver Chg

2Bh
(Version Change)

6Fh
(Sensor Specific)

Generates an event

when the IPMI FW

changes

Offset 1: Firmware / Software

change detected

10

IPMI Watchdog

23h
(Watchdog 2)

6Fh
(Sensor Specific)

OS Watchdog

Offset 0: Timer expired
Offset 1: Board Reset
Offset 2: Power Down
Offset 3: Power Cycle
Offset 8: Timer Interrupt
See IPMI v1.5 table 36.3,

Sensor type code 23h

(Watchdog 2) for sensor

definition

11

Board Reset

CFh
(OEM Kontron

Reset Sensor)

03h
(Digital Discrete)

Type and source of

Board Reset

Offset 0: Warm Reset
Offset 1: Cold Reset
See OEM sensor table, Sensor

type code CFh for sensor

definition

12

Temp MMC

01h
(Temperature)

01h
(Threshold Based)

Temperature Sensor

of the outlet region

Sensor is only readable when

Payload Power is on

13

Temp NPU

01h
(Temperature)

01h
(Threshold Based)

Temperature Sensor

of the NPU

Sensor is only readable when

Payload Power is on

14

Temp DIMM

01h
(Temperature)

01h
(Threshold Based)

Temperature Sensor

of the DIMM memory)

Sensor is only readable when

Payload Power is on.

15

Vcc +12V

02h
(Voltage)

01h
(Threshold Based)

Voltage on 12v board

power supply

Sensor is only readable when

Payload Power is on.

16

Vcc +5V

02h
(Voltage)

01h
(Threshold Based)

Voltage on 5v board

power supply

Sensor is only readable when

Payload Power is on.

17

Vcc +3.3V

02h
(Voltage)

01h
(Threshold Based)

Voltage on 3.3v board

power supply

Sensor is only readable when

Payload Power is on.